中廣核地下室人防工程監(jiān)理實(shí)施細(xì)則.doc
《中廣核地下室人防工程監(jiān)理實(shí)施細(xì)則.doc》由會(huì)員分享,可在線閱讀,更多相關(guān)《中廣核地下室人防工程監(jiān)理實(shí)施細(xì)則.doc(27頁(yè)珍藏版)》請(qǐng)?jiān)谘b配圖網(wǎng)上搜索。
上海中廣核技術(shù)產(chǎn)業(yè)研發(fā)中心工程 監(jiān)理實(shí)施細(xì)則 (地下室人防工程) 專業(yè)監(jiān)理工程師: 總監(jiān)理工程師: 上海申海建設(shè)監(jiān)理有限公司 中廣核技術(shù)產(chǎn)業(yè)研發(fā)中心項(xiàng)目監(jiān)理部 2010年8月 目 錄 一、工程概況····················································································································3 二、(人防區(qū)域)設(shè)計(jì)要求·······························································································3 三、監(jiān)理依據(jù)···················································································································4 四、監(jiān)理目標(biāo)····················································································································4 五、監(jiān)理準(zhǔn)備工作············································································································5 六、監(jiān)理工作流程············································································································5 七、施工難點(diǎn)及監(jiān)理重點(diǎn)······························································································11 八、監(jiān)理預(yù)控要點(diǎn)··········································································································12 九、監(jiān)理工作方法、措施及工程控制要點(diǎn)·································································12 一、工程概況 1.項(xiàng)目名稱:上海中廣核技術(shù)產(chǎn)業(yè)研發(fā)中心 2.子項(xiàng)目名稱:包括地下室、產(chǎn)業(yè)中心、研發(fā)中心、圖文中心、行政中心、會(huì)議中心、服務(wù)中心、門衛(wèi)8個(gè)子項(xiàng)目 3.參建單位: 建設(shè)單位:上海中廣核工程科技有限公司 設(shè)計(jì)單位:同濟(jì)大學(xué)建筑設(shè)計(jì)研究院(集團(tuán))有限公司; 監(jiān)理單位:上海申海建設(shè)監(jiān)理有限公司 施工單位:廣廈建設(shè)集團(tuán)有限責(zé)任公司 4.工程地址:上海市閔行區(qū)紫竹科學(xué)園區(qū)東川路南、淡水河?xùn)|、紫星路北,吳涇鎮(zhèn)工—52號(hào)地塊 5.建筑面積:總建筑面積109832m2,其中地下室建筑面積32112m2(人防防護(hù)單元建筑面積2000m2),建筑基底面積18595 m2 6.建筑層數(shù):地下一層、地上4及5層,建筑最高度24m 7.結(jié)構(gòu)性質(zhì):抗震設(shè)防烈度7度、設(shè)計(jì)使用年限50年、安全等級(jí)二級(jí) 二、(人防區(qū)域)設(shè)計(jì)要求 1.人防區(qū)域:①~⑧/~軸內(nèi)設(shè)置人防地下室,建筑面積2000m2,地下室頂板室外部分覆土厚度450mm。 2.人防等級(jí):甲類、核武器抗力級(jí)別6級(jí)、常規(guī)武器抗力級(jí)別6級(jí),防化等級(jí)丙級(jí),防水等級(jí)二級(jí)。 3.防護(hù)單元:防護(hù)單元建筑面積2000m2,人防使用面積1900 m2、掩護(hù)面積1400 m2掩護(hù)人數(shù)1400人。 4.出入口:三個(gè)出入口,戰(zhàn)時(shí)主要出入口利用室外汽車坡道設(shè)置;戰(zhàn)時(shí)次要出入口利用人防地下室東北側(cè)樓梯,人防區(qū)西側(cè)設(shè)置一個(gè)戰(zhàn)時(shí)人員疏散口 5.進(jìn)、排風(fēng)口:排風(fēng)口設(shè)防爆波活門,擴(kuò)散室采用超壓排風(fēng)方式;進(jìn)風(fēng)口設(shè)進(jìn)風(fēng)豎井,防爆波活門、擴(kuò)散室、除塵濾毒室和進(jìn)風(fēng)機(jī)房。 6.人防與非人防部分平時(shí)出入口臨戰(zhàn)封堵:共計(jì)封堵4處:鋼筋砼預(yù)制梁臨戰(zhàn)封堵2處、密閉通道1處(不計(jì)入臨戰(zhàn)轉(zhuǎn)換工作量)、鋼筋砼防護(hù)密閉門臨戰(zhàn)封堵1處。 7.地下室防水等級(jí)為二級(jí),抗?jié)B等級(jí)P6。 三、監(jiān)理依據(jù) 1人防基礎(chǔ)結(jié)構(gòu)設(shè)計(jì)圖紙,以及有關(guān)圖紙會(huì)審紀(jì)要、設(shè)計(jì)變更、技術(shù)核定單等。 2.工程招標(biāo)文件、合同及補(bǔ)充協(xié)議。 3.上級(jí)及國(guó)家政府機(jī)關(guān)頒發(fā)的施工規(guī)范、規(guī)定。 4.國(guó)家及上海市施工、驗(yàn)收規(guī)范,主要包括: ①《混凝土結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范》 GB50204-2002 ②《鋼筋焊接及驗(yàn)收規(guī)范》 JGJ18—96 ③《建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)》 GB50300-2001 ④《混凝土結(jié)構(gòu)施工圖平面整體表示方法制圖規(guī)則和構(gòu)造詳圖》 03G101-1 ⑤《地下防水工程質(zhì)量驗(yàn)收規(guī)范》 GB50208-2002 ⑥《人民防空工程質(zhì)量檢驗(yàn)評(píng)定標(biāo)準(zhǔn)》 RFJ 01—2002 5.人防標(biāo)準(zhǔn)圖集 DBJT08-10-79 97滬防-561、562 6.經(jīng)審批的施工組織設(shè)計(jì)、施工方案等。 四、監(jiān)理目標(biāo) 1.質(zhì)量目標(biāo):一次驗(yàn)收合格。 2.進(jìn)度目標(biāo):在合同工期內(nèi)竣工。 3安全監(jiān)理目標(biāo):無(wú)重大安全事故和管線事故,爭(zhēng)創(chuàng)市級(jí)文明工地。 五、監(jiān)理準(zhǔn)備工作 1.人防地下室施工前,監(jiān)理組向公司辦公室提供資源配備申請(qǐng),包括與本工程相配套人員、檢測(cè)設(shè)備、規(guī)范、標(biāo)準(zhǔn)圖集等。 2.監(jiān)理組熟悉施工圖紙及國(guó)家相應(yīng)的人防規(guī)范等。 3.編寫人防監(jiān)理細(xì)則并進(jìn)行交底。 4.總監(jiān)組織監(jiān)理組進(jìn)行人防監(jiān)理專業(yè)知識(shí)學(xué)習(xí)。 5.檢查施工單位設(shè)備、材料、人員準(zhǔn)備情況,是否按既定的施工方案準(zhǔn)備。 六、監(jiān)理工作流程 1.施工組織設(shè)計(jì)(方案)審批程序 修改補(bǔ)充 提出修改意見(jiàn) 施工組織設(shè)計(jì)申報(bào) 承包單位 初 審 各專業(yè)監(jiān)理工程師 向施工單位詢問(wèn)和落實(shí)主要問(wèn)題 各專業(yè)監(jiān)理工程師 監(jiān)理組會(huì)審 項(xiàng)目總監(jiān)主持,各專業(yè)監(jiān)理工程師參加 施工組織設(shè)計(jì)審批 項(xiàng)目總監(jiān) 將批件返回承包單位并送業(yè)主 施工組織設(shè)計(jì)付諸實(shí)施 督促承包單位進(jìn)行質(zhì)量安全技術(shù)交底 2.分包商資格審查程序 總包單位提供合格分供商名錄 監(jiān)理工程師審查分包工程的申請(qǐng)報(bào)告: a.分包單位的資質(zhì)證明; b.分包工程項(xiàng)目及內(nèi)容; c.分包工程數(shù)量及金額。 總監(jiān)理工程師 審批 承包商、分包方簽訂 工程分包合同 分包方進(jìn)入工地施工 必要時(shí)進(jìn)行實(shí)地考察 不 同意 3.施工圖紙?jiān)O(shè)計(jì)交底程序 布置圖紙?jiān)O(shè)計(jì)交底工作 總監(jiān)理工程師 總監(jiān)主持由業(yè)主、設(shè)計(jì)、施工、監(jiān)理四方參加施工圖紙?jiān)O(shè)計(jì)交底 整理圖紙各專業(yè)工種問(wèn)題清單 熟悉施工圖紙多提出問(wèn)題 各專業(yè)監(jiān)理工程師 監(jiān)理內(nèi)部會(huì)審 與業(yè)主、設(shè)計(jì)磋商落實(shí)清單中問(wèn)題處理意見(jiàn)并整理歸檔 4.人防基礎(chǔ)工程質(zhì)量控制流程 合格 不合格 存在問(wèn)題 合格 不合格 存在問(wèn)題 不合格 復(fù)查軸線及標(biāo)高 監(jiān)理工程師 復(fù)查結(jié)果 返工 承包人 地基處理施工 填報(bào)地基處理質(zhì)量驗(yàn)收簽證 承包人 監(jiān)理師發(fā)出口頭或書面指令 整改 承包人根據(jù)設(shè)計(jì)和規(guī)范要求自檢合格,并報(bào)有關(guān)資料 現(xiàn)場(chǎng)檢查 現(xiàn)場(chǎng)監(jiān)理工程師 現(xiàn)場(chǎng)抽樣檢查 專業(yè)監(jiān)理工程師 檢查結(jié)果 返工 承包人 監(jiān)理工程師簽字 基礎(chǔ)施工 填報(bào)基礎(chǔ)工程質(zhì)量驗(yàn)收簽證 承包人 現(xiàn)場(chǎng)檢查 現(xiàn)場(chǎng)監(jiān)理工程師 現(xiàn)場(chǎng)抽樣檢查 專業(yè)監(jiān)理工程師 檢查結(jié)果 承包人根據(jù)設(shè)計(jì)和規(guī)范要求自檢合格,并報(bào)有關(guān)資料 返工 承包人 總監(jiān)理工程師簽字 監(jiān)理師發(fā)出口頭和書面指令 整改 5.鋼筋混凝土工程質(zhì)量控制流程 合格 不合格 合格 不合格 驗(yàn)收軸線、標(biāo)高 監(jiān)理工程師 鋼筋工程自檢合格 承包人 鋼筋工程隱蔽驗(yàn)收 監(jiān)理工程師 驗(yàn)收結(jié)果 模板工程自檢合格 承包人 模板工程驗(yàn)收 監(jiān)理工程師 驗(yàn)收結(jié)果 整改 承包人 驗(yàn)收 承包人 檢查澆筑前的準(zhǔn)備工作 監(jiān)理工程師、承包人 簽署混凝土澆筑 監(jiān)理工程師 混凝土澆筑 承包人 6.材料審批程序 材料及設(shè)備進(jìn)場(chǎng)前 填寫“材料及設(shè)備進(jìn)場(chǎng)報(bào)審表” 承包方 提交材料有關(guān)文件,如質(zhì)保書、合格證、準(zhǔn)用證、進(jìn)滬許可證、商檢報(bào)告等 承包方 審核 監(jiān)理工程師 不準(zhǔn)進(jìn)場(chǎng) 材料進(jìn)入施工現(xiàn)場(chǎng) 按規(guī)定批量自檢填寫 材料報(bào)審表 承包方 審核檢查 監(jiān)理工程師 進(jìn)場(chǎng)使用 監(jiān)理歸檔 監(jiān)理抽檢 通知禁止使用 自費(fèi)運(yùn)出現(xiàn)場(chǎng) 監(jiān)理按抽樣檢驗(yàn)頻率和現(xiàn)場(chǎng)發(fā)現(xiàn)材料有問(wèn)題時(shí)進(jìn)行抽檢 7.隱蔽工程驗(yàn)收程序 進(jìn)行下一道工序施工 隱蔽工程施工完成 承包方 簽署隱蔽工程驗(yàn)收單 監(jiān)理工程師 隱蔽工程自檢合格 承包方 填寫隱蔽工程報(bào)驗(yàn)單 承包方 對(duì)所報(bào)隱蔽工程 檢查驗(yàn)收 監(jiān)理工程師 整改 承包方 七、施工難點(diǎn)及監(jiān)理重點(diǎn) 人防工程與普通民用建筑不同,在施工中往往忽略他們的差異性而產(chǎn)生質(zhì)量通病,這是本工程監(jiān)理的重點(diǎn)亦是本工程的難點(diǎn)。監(jiān)理將對(duì)以下方面予以重點(diǎn)控制: 1.土建部分: ·底板為梁板式,梁板頂標(biāo)高一致,板的鋼筋在梁主筋下。 ·墻模板的支設(shè)要求用有止水片的穿墻螺桿支模。 ·有檻臨戰(zhàn)封堵處要有角鋼護(hù)角。 ·有檻門要有T型角鋼護(hù)角。 2.安裝部分: ·防爆波閥門專用防爆波閥門。 ·套管為3~5mm鋼板機(jī)械卷制,不能用無(wú)縫鋼管。 ·人防地下室結(jié)構(gòu)施工完成后,要在回填土施工后(穿墻螺桿不要進(jìn)行處理)請(qǐng)人防質(zhì)檢站驗(yàn)收合格,方能進(jìn)行裝修施工。 八、監(jiān)理預(yù)控要點(diǎn) 1.加強(qiáng)對(duì)施工單位資質(zhì)審查,要求承建單位建立健全質(zhì)量保證體系并確保其有效的運(yùn)轉(zhuǎn)。 2.監(jiān)理人員認(rèn)真熟悉施工圖,了解工程特點(diǎn)(特別是按照人防圖集對(duì)照)、工程關(guān)鍵部位的施工方法、質(zhì)量要求;并對(duì)圖紙中存在的問(wèn)題通過(guò)建設(shè)單位向設(shè)計(jì)單位提出意見(jiàn)和建議。 3.監(jiān)理人員參加設(shè)計(jì)技術(shù)交底會(huì),對(duì)圖紙存在的問(wèn)題和難以施工部位和設(shè)計(jì)人員討論具體實(shí)施方案。 4.組織監(jiān)理組對(duì)施工單位報(bào)審的施工方案進(jìn)行系統(tǒng)的審核。 5.嚴(yán)格對(duì)進(jìn)場(chǎng)的原材料進(jìn)行質(zhì)量控制。 6.及時(shí)派測(cè)量監(jiān)理師對(duì)本工程定位放線進(jìn)行復(fù)合。 九、監(jiān)理工作的方法、措施及過(guò)程控制要點(diǎn) 1.原材料的控制 ①鋼筋:進(jìn)場(chǎng)鋼筋必須有出廠質(zhì)量證明書和實(shí)驗(yàn)報(bào)告單,按爐罐號(hào)和直徑分別檢查鋼筋標(biāo)志和外觀質(zhì)量,符合后(每60噸為一取樣單位)隨機(jī)取樣,送樣;合格后方可使用。 ②水泥:進(jìn)場(chǎng)水泥必須具有產(chǎn)品生產(chǎn)許可證、質(zhì)量證明書(同廠生產(chǎn)的水泥一個(gè)編號(hào)為一個(gè)取樣單位)進(jìn)行取樣、送樣合格后方可使用。 ③混凝土:本工程采用商品混凝土,混凝土到場(chǎng)要有配合比;在混凝土澆筑地點(diǎn)隨機(jī)抽?。ú怀^(guò)200立方米同配合比混凝土)取樣不得少于一次?;炷撂涠纫鲜┕ひ?guī)范要求。 ④砂漿:每天砌體中各種強(qiáng)度等級(jí)砂漿采用重量配合比并進(jìn)行取樣不得少于一次。 ⑤骨料(砂、石)進(jìn)場(chǎng)要有出廠合格證;(同產(chǎn)地、同規(guī)格以400立方米、600t為一取樣單位)取樣、送樣;合格后方可使用。 ⑥砌體:進(jìn)場(chǎng)要有出廠合格證;(對(duì)不同規(guī)格,按照見(jiàn)證、取樣手冊(cè)所規(guī)定數(shù)量為一取樣單位)隨機(jī)取樣、送樣;合格后方可使用。 ⑦防水卷材及防水涂料按規(guī)范進(jìn)行取樣、送檢,合格后方可使用。 ⑧須有進(jìn)滬證的產(chǎn)品必須有“上海市準(zhǔn)用證”。 ⑨人防工程專用設(shè)備必須由人防部門認(rèn)可的專業(yè)生產(chǎn)工廠生產(chǎn)的合格產(chǎn)品。 2.人防鋼筋混凝土地下室的控制 A、鋼筋工程的質(zhì)量控制 ①檢查鋼筋標(biāo)牌、爐號(hào)、廠家及出廠質(zhì)量合格證、實(shí)驗(yàn)報(bào)告,并按規(guī)定要求施工現(xiàn)場(chǎng)進(jìn)行復(fù)試。 ②試驗(yàn)不合格的鋼筋,不能用于工程上,并及時(shí)報(bào)告有關(guān)上級(jí)和監(jiān)理工程師做處理,并記錄在案。 ③鋼筋加工制作: ·施工單位應(yīng)熟悉圖紙,向監(jiān)理工程師提供加工方案,加工翻樣,加工料表,準(zhǔn)備工作情況; ·操作人員必須實(shí)行掛牌制,焊工持證上崗; ·鋼筋的級(jí)別、鋼號(hào)和直徑必須符合設(shè)計(jì)要求,帶有顆粒狀或鱗片狀老化銹蝕的鋼筋不能用,需要代換鋼筋時(shí),必須上報(bào)監(jiān)理工程師,應(yīng)征得設(shè)計(jì)的同意,否則不得以其他鋼筋代換; ·加強(qiáng)鋼筋翻樣的控制。 ④鋼筋加工成品要求: ·鋼筋的形狀、尺寸必須符合圖紙要求; ·鋼筋的表面應(yīng)潔凈、無(wú)損傷、油漆和銹蝕; ·鋼筋應(yīng)平直無(wú)曲折,表面不得有明顯的擦傷; ·鋼筋的彎折與彎鉤應(yīng)符合設(shè)計(jì)及規(guī)范要求; B、底板鋼筋的檢查 ①底板工程的關(guān)鍵部位及節(jié)點(diǎn): ·口部防護(hù)密閉門、密閉門、防爆活門下檻梁綁扎; ·臨空墻、密閉墻、防護(hù)單元隔墻的插筋(位置、彎錨朝向應(yīng)正確); ·連通口、通風(fēng)豎井處鋼筋插筋; ·車道口部、防護(hù)單元隔墻處臨戰(zhàn)封堵下檻鋼筋綁扎; ·外墻轉(zhuǎn)角、丁字墻交接處定位插筋; ·墻底板、附墻柱施工縫處鋼板止水帶處墻板水平筋的結(jié)構(gòu)處理; ②各個(gè)口部密閉門(即第二道門)兩側(cè)的尺寸應(yīng)注意,即門軸側(cè)寬度≥350mm,另一側(cè)為≥150mm,否則門扇安裝后難以開(kāi)啟到位。 ③各個(gè)口部防護(hù)密閉門(即第一道門)兩側(cè)箍筋為閉口箍,密閉門即第二道門兩側(cè)可按墻板水平筋綁扎。 ④樓梯間處的防護(hù)密閉門如果側(cè)向設(shè)置,其側(cè)面應(yīng)設(shè)置附墻抗爆柱或抗爆梁,出墻面≥100mm,寬200~250mm,或門框墻體縮進(jìn)100mm。 ⑤所有墻板水平筋在端部均應(yīng)制彎錨,不得使用直條筋,彎錨長(zhǎng)度≥10d。 ⑥三防門下檻梁如果在底板混凝土澆搗后,如發(fā)現(xiàn)箍筋偏低,混凝土保護(hù)層增大,均應(yīng)進(jìn)行調(diào)整,采用開(kāi)口箍與原有箍筋焊接,并將下檻梁水平筋重新移至上層綁扎。焊接縫長(zhǎng)度10d,要求焊縫飽滿并須敲掉焊渣。 ⑦進(jìn)行臨戰(zhàn)封堵的豎向及上部角框焊制時(shí),要求角框垂直、平整,焊縫飽滿,敲掉焊渣。豎向角須壓在下部角框上焊接,兩角平直、對(duì)齊。角框背面應(yīng)按設(shè)計(jì)要求焊接錨筋。錨筋采用Ⅰ級(jí)鋼,須做錨鉤,采用Ⅱ鋼錨固長(zhǎng)度均應(yīng)達(dá)到30d。 ⑧如防護(hù)密閉門、密閉門設(shè)計(jì)為有檻門,可在底板混凝土澆搗后,在墻板鋼筋綁扎后即進(jìn)行角框安裝,要求角框面與混凝土結(jié)構(gòu)面平、齊。 ⑨在進(jìn)行墻板、柱鋼筋綁扎前,應(yīng)首先按照控制標(biāo)高進(jìn)行測(cè)量,作出水平標(biāo)高控制點(diǎn),進(jìn)行各項(xiàng)門框、安裝預(yù)埋、結(jié)構(gòu)標(biāo)高控制。 在進(jìn)行三防門門框墻鋼筋綁扎是時(shí)應(yīng)先將門框鋼筋綁扎好,然后安裝三防門門框,再綁扎門框上部墻板梁。只有再門框上部墻板梁鋼筋綁扎完成后才能進(jìn)行電氣管預(yù)埋。 三防門角框安裝后進(jìn)行各個(gè)面垂直調(diào)整,并采用鋼支架將門框支撐牢固,嚴(yán)禁將角框與門框墻鋼筋焊接在一起。 在進(jìn)行三防門門框安裝時(shí)應(yīng)檢查門框位置的正確與否,門軸側(cè)邊應(yīng)≥350mm,另一面≥150mm,否則門扇安裝后難以開(kāi)啟到位。 臨空墻、防護(hù)單元隔墻如有預(yù)留洞,應(yīng)設(shè)置雙面角鐵框,角鐵均應(yīng)≥80mm,一般為100mm。 防護(hù)單元隔墻的背靠三防護(hù)門均為防護(hù)密閉門,其鋼筋斷面一般為450mm。各個(gè)三防門門框在安裝后才能綁扎門洞上部過(guò)梁板鋼筋,才能進(jìn)行電氣安裝,因此,必須作好施工安排。另外在三防門門框安裝好后,所有門框墻鋼筋均須重新進(jìn)行整理,這是必須進(jìn)行的一道工序。 綁扎防爆活門鋼筋應(yīng)注意斷面尺寸,一般斷面為≥450mm。 進(jìn)行頂板隱蔽工程檢查中勿忘三防門吊裝的檢查,吊鉤規(guī)格、形狀、安裝位置按施工土和規(guī)范檢查。 口部工程的隱蔽工程檢查中勿忘側(cè)壓管的檢查。 墻頂板交角處節(jié)點(diǎn)鋼筋的綁扎應(yīng)牢固、平直。外墻外側(cè)豎筋上部彎錨筋應(yīng)捋須平直并與頂板筋綁扎。 應(yīng)注意檢查墻板、頂板下部混凝土墊塊埔設(shè),混凝土嚴(yán)禁露筋。 外墻轉(zhuǎn)角、丁字墻交接處點(diǎn)鋼筋綁扎應(yīng)按施工圖和規(guī)范規(guī)定檢查。 墻板拉結(jié)筋布置應(yīng)梅花形排列,勾住外層鋼筋。 臨戰(zhàn)封堵除了預(yù)埋角框安裝外,其余設(shè)計(jì)圖紙所標(biāo)的封堵鋼板等暫不施工,臨戰(zhàn)前施工。 墻板預(yù)留孔及預(yù)埋管處的構(gòu)造鋼筋設(shè)置應(yīng)按施工圖和規(guī)范進(jìn)行檢查。 連通口處后封堵混凝土可按一次性澆搗處理,配置雙面Ф8、200*200網(wǎng)片。 各個(gè)三防門側(cè)安裝的4根戰(zhàn)時(shí)穿線管應(yīng)要求標(biāo)高、位置一致,豎向擺放應(yīng)垂直,連通口處可橫放,要求平直。 C、鋼筋焊接接頭的質(zhì)量要求: ①焊工必須經(jīng)過(guò)培訓(xùn),合格后方能上崗; ②批量鋼筋焊接前,必須根據(jù)施工條件試焊,合格后方能大批量焊接; ③鋼筋焊接質(zhì)量按規(guī)范要求施工。 ④鋼筋焊接加強(qiáng)加工前檢查和加工中間檢查,焊接不合格的鋼筋不能進(jìn)入安裝現(xiàn)場(chǎng)。 D、鋼筋綁扎與安裝: ①鋼筋綁扎前要求彈出位置線標(biāo)記,分出雙層鋼筋位置線,尤其是梁柱、防護(hù)隔墻、臨空墻、主筋位置必須準(zhǔn)確,采取防位移措施; ②鋼筋接頭位置要符合施工驗(yàn)收規(guī)范和設(shè)計(jì)要求; ③檢驗(yàn)質(zhì)量標(biāo)準(zhǔn)按GB 50204-2002混凝土結(jié)構(gòu)施工質(zhì)量驗(yàn)收規(guī)范第五節(jié)鋼筋分項(xiàng)工程和人民防空工程質(zhì)量檢驗(yàn)評(píng)定標(biāo)準(zhǔn)的有關(guān)規(guī)定。 E、混凝土工程和防水混凝土工程: ①混凝土開(kāi)盤前的質(zhì)量控制 ·檢查攪拌后臺(tái)的計(jì)量控制是否符合要求,使用商品混凝土的必須對(duì)攪拌站的資質(zhì)及質(zhì)量保證體系進(jìn)行審查; ·混凝土澆筑前施工單位必須向監(jiān)理工程師提交原材料的材質(zhì)證明和試驗(yàn)報(bào)告(包括商品混凝土),水泥應(yīng)有出廠日期,出廠合格證、水泥強(qiáng)度、防滲等級(jí)、安定性試驗(yàn)報(bào)告,砂石的試驗(yàn)報(bào)告和已通過(guò)試配的混凝土配比單。 ·混凝土澆筑前認(rèn)真組織水暖衛(wèi)、電氣、土建聯(lián)合檢查,辦好隱蔽驗(yàn)收,申報(bào)施工方案,報(bào)監(jiān)理工程師審核、檢查批準(zhǔn)后,方能開(kāi)始澆筑。 ②監(jiān)理工程師在澆筑過(guò)程中進(jìn)行跟蹤檢查,對(duì)混凝土進(jìn)行隨機(jī)抽查,發(fā)現(xiàn)缺陷及時(shí)處理。 ③配合比的控料 混凝土配合比的計(jì)算和試驗(yàn)應(yīng)符合《普通混凝土配合比設(shè)計(jì)技術(shù)規(guī)定》按試配結(jié)果由實(shí)驗(yàn)室負(fù)責(zé)人簽發(fā)配比通知單; ④商品混凝土攪拌、運(yùn)輸、泵送質(zhì)量控制 ⑤施工現(xiàn)場(chǎng)混凝土質(zhì)量管理 現(xiàn)場(chǎng)必須具備混凝土試塊的制作、養(yǎng)護(hù)條件,有健全的管理制度; ·現(xiàn)場(chǎng)試驗(yàn)員必須經(jīng)培訓(xùn)、考核、持證上崗; ·混凝土施工前應(yīng)作技術(shù)、安全交底,并應(yīng)具備混凝土養(yǎng)護(hù)條件,特別是季節(jié)性施工期間的防水、防凍措施,要設(shè)專人負(fù)責(zé)實(shí)施; ·混凝土攪拌、運(yùn)送、澆筑等過(guò)程中任何人不得擅自加水。 F、孔口防護(hù)工程的控制 ①孔口防護(hù)工程的質(zhì)量監(jiān)理程序 空口防護(hù)設(shè)備或預(yù)埋管制作,報(bào)監(jiān)理審核 孔口防護(hù)工程測(cè)量軸線、標(biāo)高,報(bào)監(jiān)理審核 監(jiān)理檢查、復(fù)驗(yàn) 鋼筋綁扎,預(yù)埋件、監(jiān)理巡視 施工單位自檢查 監(jiān)理隱蔽工程驗(yàn)收 模板工程施工單位自檢 監(jiān)理單位檢查 混凝土工程監(jiān)理旁站 不合格 不合格 發(fā)通知 發(fā)通知 不合格 發(fā)通知 不合格 合格 發(fā)通知 序號(hào) 防護(hù)設(shè)備名稱 型號(hào) 門洞(寬×高)mm(B×H) 門外通道最小寬度(mm)F 門外通道最小凈高(mm)F 門扇最小開(kāi)啟寬度(mm)L 較頁(yè)側(cè)門框最小寬度(mm)D 門扇材料型式 門坎高度(mm)C 門扇質(zhì)量(單扇)(kg) 吊環(huán)直徑mm 1 密閉門 M716 700×1600 1200 2000 1050 350 鋼筋混凝土平板 ≥150 12 2 M820 800×2000 1300 2400 1150 350 鋼筋混凝土平板 150 16 3 M1020 1000×2000 1500 2400 1400 350 鋼筋混凝土平板 150 16 4 M1320 1300×2000 1800 2400 1700 350 鋼筋混凝土平板 150 20 5 M1520 1500×2000 2000 2400 1900 350 鋼筋混凝土平板 150 20 ②人防工程常用密閉門基相應(yīng)門框尺寸 G、施工過(guò)程控制 ①在主體工程鋼筋綁扎期間,對(duì)孔口的防護(hù)密閉門、密閉門的位置、尺寸進(jìn)行仔細(xì)測(cè)量放樣。 ②門框墻施工應(yīng)嚴(yán)格按照施工圖圖紙施工,并符合下列要求: ·防護(hù)密閉門門框墻及截面厚度的尺寸不小于300mm。 ·兩個(gè)防護(hù)單元間的門框及門檻截面厚度不小于500mm。 ·門框墻的受力鋼筋直徑不應(yīng)小于12mm,間距不大于250mm,配筋率不小于0.25%。 ·門洞四角的內(nèi)外側(cè)應(yīng)配置兩根直徑16mm斜向鋼筋,其長(zhǎng)度不應(yīng)小于1000mm。 ·防護(hù)密閉門、密閉門的鋼制門框與門框墻之間有足夠的連接強(qiáng)度,并應(yīng)澆搗密實(shí),相互連成整體。 ③防護(hù)密閉門、密閉門門窗配筋,嚴(yán)格按照設(shè)計(jì)要求,并注意門的開(kāi)啟方向,防止門框左右側(cè)配筋位置差錯(cuò),如設(shè)計(jì)無(wú)門框墻的詳細(xì)配筋圖,應(yīng)參考有關(guān)人防工程標(biāo)準(zhǔn)圖集。 ④有門框的門檻鋼筋高出底板的高度應(yīng)滿足各種型號(hào)的防護(hù)密閉門和密閉門門檻建筑高度。 ⑤防護(hù)密閉門和密閉門合頁(yè)側(cè)的門框最小寬度應(yīng)滿足人防門的安裝尺寸,閉鎖側(cè)的門框最小寬度應(yīng)不會(huì)影響門扇的開(kāi)啟。 ⑥防護(hù)密閉門和密閉門的門框角鋼預(yù)埋位置方向應(yīng)準(zhǔn)確,防護(hù)密閉門的角鋼應(yīng)預(yù)埋在非人防區(qū)一側(cè),密閉門的角鋼宜預(yù)埋在染毒區(qū)一側(cè),濾毒間的密閉門角鋼應(yīng)預(yù)埋在密閉通道內(nèi),角鋼的閉鎖盒開(kāi)口大頭在下,小頭在上,門軸位置與設(shè)計(jì)施工圖一致。 ⑦預(yù)埋防護(hù)密閉門和密閉門的門扇吊鉤應(yīng)鉤住頂板上層鋼筋,吊鉤應(yīng)放置在門扇寬度的中央以門軸圓心轉(zhuǎn)45°角處,其中,F(xiàn)M25、FM(M)716的吊鉤規(guī)格為Ф12,F(xiàn)M818、FM(M)820、FM(M)1020的吊鉤鉤規(guī)格為Ф16,F(xiàn)M(M)1320、FM(M)1520的吊鉤規(guī)格為Ф20。 ⑧門框墻的混凝土澆筑應(yīng)符合以下要求: ·門框墻應(yīng)連續(xù)澆筑、振搗密實(shí)、表面平整光滑,無(wú)蜂窩、無(wú)孔洞。 ·門扇混凝土碎石最大粒徑不應(yīng)大于25mm,且不應(yīng)大于受力鋼筋最小凈距的3/4。 ·預(yù)埋鐵件應(yīng)除銹,其安裝的位‰置應(yīng)準(zhǔn)確,固定應(yīng)牢靠,門框墻上應(yīng)有預(yù)留電攬管孔,預(yù)埋管孔洞應(yīng)涂油或毒塞。 ⑨防護(hù)密閉門、密閉門的供應(yīng)商必須是人防部門認(rèn)可的專業(yè)生產(chǎn)單位生產(chǎn),報(bào)監(jiān)理單位審核。 門扇安裝應(yīng)符合下列要求: ·鋼門框支撐面的平整度不應(yīng)超過(guò)1mm,每邊不平整部分累計(jì)的長(zhǎng)度不應(yīng)大于該邊長(zhǎng)度的20%,且應(yīng)分布在2處以上;門框四邊垂直度偏差不應(yīng)超過(guò)長(zhǎng)邊的2‰。 ·門扇鋼框與鋼門框應(yīng)貼合均勻,其間隙不得大于2mm;每邊不貼合部分累計(jì)的長(zhǎng)度不應(yīng)大于該邊長(zhǎng)度的20%,且應(yīng)分布在2處以上。 ·鉸頁(yè)、閉鎖安裝位置應(yīng)準(zhǔn)確;上、下鉸頁(yè)同軸度偏差不應(yīng)超過(guò)兩鉸頁(yè)間距的1‰,且不得大于2mm。 ·雙扇拱形防護(hù)門的上、下兩斷與門框之間,均應(yīng)有50mm的間隙。 ·門扇應(yīng)啟閉靈活。 ·在門扇外表面應(yīng)標(biāo)識(shí)閉鎖開(kāi)關(guān)方向。 密封條安裝,應(yīng)符合下列要求: ·密封條接頭應(yīng)采用45°坡口搭接,每扇門的密封條接頭不得超過(guò)2處。 ·密封條應(yīng)固定牢靠,壓縮均勻;局部壓縮量允許偏差不應(yīng)超過(guò)設(shè)計(jì)壓縮量的20%。 ·密封條不得涂抹油漆。 孔口防護(hù)設(shè)施的包裝,應(yīng)符合下列要求: ·各類防護(hù)設(shè)施均應(yīng)具有產(chǎn)品出廠合格證。 ·防護(hù)設(shè)施的零、部件必須齊全,井不得銹蝕和損壞。 ·防護(hù)設(shè)施分部件包裝時(shí),應(yīng)注明配套型號(hào)、名稱和數(shù)量。 門扇、門框的運(yùn)輸,應(yīng)符合下列要求: ·門扇混凝土強(qiáng)度達(dá)到設(shè)計(jì)要求后,方可運(yùn)輸。 ·門窗和鋼框應(yīng)與車身固定牢靠。 防護(hù)設(shè)施的堆放,應(yīng)符合下列規(guī)定。 ·堆放場(chǎng)地應(yīng)平整、堅(jiān)固、無(wú)積水; ·金屬構(gòu)件不得露天堆放; ·各種防護(hù)設(shè)施應(yīng)分類堆放; ·密閉門及鋼框應(yīng)立式堆放; ·門窗水平堆放時(shí),其內(nèi)表面應(yīng)朝下;應(yīng)在兩長(zhǎng)邊放置同規(guī)格的條形墊木;在門框的跨中處不得放置墊木。 H、監(jiān)理重點(diǎn) ①檢查鋼筋、水泥、粗細(xì)骨料以及防護(hù)密閉門、密閉門、材料、設(shè)備得質(zhì)量證書、準(zhǔn)用證、生產(chǎn)許可證及有關(guān)試驗(yàn)報(bào)告。 ②在門框墻定位放樣時(shí),監(jiān)理人員仔細(xì)核對(duì)尺寸,重點(diǎn)對(duì)門框墻門前尺寸、開(kāi)啟方向的位置尺寸仔細(xì)核對(duì)。 ③對(duì)防護(hù)密閉門、密閉門框的鋼筋工程的隱蔽工程進(jìn)行檢查驗(yàn)收,重點(diǎn)檢查鋼筋骨架的尺寸、鋼筋直徑、間距、垂直度以及預(yù)埋件、管件的位置、方向等,均應(yīng)符合設(shè)計(jì)要求或有關(guān)人防標(biāo)準(zhǔn)圖集。 ④鋼筋配筋時(shí),檢查門檻的鋼筋高度是否符合各種型式門的建筑高度,核對(duì)各種型式的門合頁(yè)側(cè)和閉鎖側(cè)的門框?qū)挾饶芊駶M足開(kāi)啟的需要。 ⑤門框墻的混凝土澆筑時(shí),監(jiān)理人員旁站,督促施工單位連續(xù)澆筑和振搗密實(shí)。 ⑥防護(hù)密閉門、密閉門安裝前,檢查各扇門的平整度和在運(yùn)輸貯存過(guò)程中的受損,如有損壞影響密閉門等使用功能的應(yīng)禁止安裝。 ⑦門窗安裝時(shí),要求門扇鋼框與鋼門框貼合均勻,其不貼部分和間隙都應(yīng)符合要求。檢查上、下鉸頁(yè)同軸度的偏差。 ⑧檢查密閉封條安裝質(zhì)量、密閉條接頭搭接形式、固定牢固程度、壓縮均勻程度,均應(yīng)符合規(guī)范要求。 ⑨進(jìn)、出管線的防護(hù)密閉工程的質(zhì)量監(jiān)控: 進(jìn)、出管線的防護(hù)密閉工程指的是用于給排水、排水管、通氣管、熱水管、電纜等進(jìn)出管線的防護(hù)密閉工程。 ·當(dāng)管道穿越防護(hù)密閉隔墻時(shí),必須預(yù)埋帶有密閉翼環(huán)和防護(hù)抗力片的密閉穿墻短管。當(dāng)管道穿越密閉墻時(shí),必須預(yù)埋帶有密閉翼環(huán)的密閉穿墻短管。 ·給水管、壓力排水管、電纜電線等的密閉穿墻短管,應(yīng)按設(shè)計(jì)要求制作。應(yīng)采用厚度大于3mm的鋼管。其焊縫應(yīng)飽滿、均勻、嚴(yán)密。 ·通風(fēng)管的密閉穿墻短管,應(yīng)采用厚度2—3mm的鋼板焊接制作,其焊縫應(yīng)飽滿、均勻、嚴(yán)密。 ·密閉翼環(huán)應(yīng)采用厚度大于3mm的鋼板制作。鋼板應(yīng)平整,其翼高宜為30—50mm。密閉翼環(huán)與密閉穿墻短管的結(jié)合部位應(yīng)滿焊。 ·密閉翼環(huán)應(yīng)位于墻體厚度的中間,并應(yīng)于周圍結(jié)構(gòu)鋼筋焊牢。密閉穿墻短管的軸線應(yīng)與所在墻面垂直,管端面應(yīng)平整。 ·密閉穿墻短管兩端伸出墻面的長(zhǎng)度,應(yīng)符合設(shè)計(jì)要求。當(dāng)設(shè)計(jì)規(guī)定時(shí),應(yīng)符合下列要求: 電纜、電線穿墻短管宜為30~50mm; 給排水管穿墻短管應(yīng)大于40mm; 通風(fēng)管墻短管應(yīng)大于100mm。 ·密閉穿墻短管作套管時(shí),應(yīng)符合下列要求: ·在套管與管道之間應(yīng)用密封材料填充密實(shí),并應(yīng)在管口兩端進(jìn)行密閉處理。填料長(zhǎng)度應(yīng)為管徑的3~5倍,且不得小于100mm; ·管道在套管內(nèi)不得有接口; ·套管內(nèi)徑應(yīng)比管道外徑大30~50mm。 ·密閉穿墻短管應(yīng)在朝向核爆炸沖擊波加裝防護(hù)抗力片??沽ζ瞬捎煤穸却笥?mm的鋼板制作??沽ζ喜劭趯挾葢?yīng)與所穿越的管線外徑相同;兩快抗力片的槽口必須對(duì)插。 ·當(dāng)同一處有多根管線需作穿墻密閉處理時(shí),可在密閉穿墻短管兩端各焊上一塊密閉翼環(huán)應(yīng)與所在墻體的鋼筋焊牢,且不得露出墻面。 給水排水工程的質(zhì)量控制 A、監(jiān)理控制目標(biāo)內(nèi)容 給水排水工程是人民防空工程的一個(gè)重要分部工程。該分部工程一般包括下列七個(gè)分項(xiàng)工程: ·給水管道安裝 ·給水管道附件及衛(wèi)生器具給水配件安裝。 ·給水附屬設(shè)備安裝。 ·排水管道安裝。 ·衛(wèi)生器具安裝。 ·洗消器具安裝。 ·立式水泵安裝。 B、有關(guān)人防工程專業(yè)要求的給排水工程的預(yù)埋和安裝 ·所有穿越人防工程圍護(hù)結(jié)構(gòu)、臨空墻、密閉墻的給排水管道預(yù)埋帶有密閉翼環(huán)的密閉穿墻短管作為套管。 預(yù)埋時(shí)檢查預(yù)埋套管材質(zhì)、規(guī)格、標(biāo)高、軸線位置必須按設(shè)計(jì)要求、圖集施工。檢查在臨空墻及人防兩個(gè)單元之間是否按施工圖或規(guī)范、圖集預(yù)埋套管,固定法蘭與套管之間必須兩面滿焊,緊貼墻面的固定法蘭與套管之間焊逢必須平整,放置時(shí)套管與墻面必須垂直,固定法蘭必須垂直緊貼模板,預(yù)埋時(shí)與混凝土結(jié)合部位不能油漆,尤其的露出部位要涂刷防腐漆。 穿墻套管內(nèi)的管段不得有接頭,穿墻管與套管的填充材料一般用瀝青麻絲,用于填料的溫度>40°時(shí),應(yīng)用瀝青石棉繩。臨空墻的在填料完成后要焊抗力擋板,抗力擋板的外圓要和套管的固定法蘭滿焊,抗力擋板的內(nèi)圓不得與穿墻管段焊接。 ·洗消排水管設(shè)計(jì)要求采用Dg80鍍鋅管絲扣連接,宜用角鋼支架、U型卡固定,鍍鋅鋼管不得用電焊焊接固定。預(yù)埋時(shí)要注意標(biāo)高,鋼質(zhì)管堵的上平面在土建標(biāo)高下5mm,伸入洗消排水井的管段要注意標(biāo)高,在建筑物下一0.25m,離洗消排水井壁0.25m以上,滿足井蓋閉合及安裝閥門,閥門嚴(yán)禁采用活接連接。 ·洗消給水管穿越密閉墻必須采用φ70的穿墻套管。在人防內(nèi)部設(shè)置的閥門前段嚴(yán)禁采用活接連接,Dg以上的管道按圖集制作預(yù)埋套管。 ·如設(shè)計(jì)要求排水管道采用防爆地漏,預(yù)埋時(shí)必須注意標(biāo)高,上平面在土建標(biāo)高以下5mm,要直接預(yù)埋在混凝土內(nèi)。 ·自動(dòng)消防噴淋管道固定吊、支架設(shè)置應(yīng)合理、牢固,不應(yīng)有晃動(dòng)。成排地噴淋管道、噴頭及吊支架應(yīng)一直線,Dg50以上的管道不能直接用U型卡受力,要受力在角鋼上,宜設(shè)置龍門支架固定。支架的材質(zhì),型號(hào)、規(guī)格必須按設(shè)計(jì)要求,施工規(guī)范制作、安裝。吊架與噴頭之間的距離不直小于300mm,與末端噴頭之間不宜大于750mm。吊架的間距不宜大于3.6m。 ·管道或支吊架件在涂刷底漆前,必須清除表面的灰塵、污垢、銹斑、焊渣等物,涂刷應(yīng)均勻,顏色一致,涂膜應(yīng)附著牢固,無(wú)剝落、皺紋、氣泡、針孔等缺陷。管道安裝后不宜涂漆部位應(yīng)預(yù)先涂漆,涂層應(yīng)完整、無(wú)損傷、流淌等現(xiàn)象。 ·法蘭連接的管道,緊固螺栓的方向應(yīng)一致,螺桿露出螺母部分宜為螺桿直徑的1/2,長(zhǎng)短要一致。 ·進(jìn)入人防工程的給水管道必須在工程內(nèi)側(cè)設(shè)工作壓力≥1.0Mpa的閘閥,在兩個(gè)防護(hù)單元進(jìn)出管線,必須在進(jìn)出兩側(cè)設(shè)工作壓力≥1.0Mpa的閘閥。 ·室內(nèi)消火栓應(yīng)設(shè)在明顯易于取用的地點(diǎn),栓口離地高度為1.1m,其出水方向直向下或與設(shè)置消火栓的墻面成900角,消防配水立管固定支架高度距地面應(yīng)為1.5~1.8m,但在單位工程或小區(qū)中高度應(yīng)一致。 10、 管道焊接時(shí),應(yīng)根據(jù)鋼管的壁厚在對(duì)口處留有一定的間隙(一般1.5~3.0mm),并按規(guī)定坡口,焊縫應(yīng)平整、飽滿、焊波均勻一致。焊完后立即出去渣皮、飛濺,并應(yīng)將焊縫表面處理干凈,焊縫及標(biāo)志在試壓前不應(yīng)涂漆。鍍鋅鋼管不應(yīng)采用焊接連接,被破壞的鍍鋅表面及螺紋露出部分應(yīng)做防腐處理。 C、監(jiān)理程序 給水排水工程施工質(zhì)量監(jiān)理工作分為下列三個(gè)階段:監(jiān)理工作準(zhǔn)備,工程施工過(guò)程監(jiān)理,工程質(zhì)量的檢驗(yàn)評(píng)定、工程驗(yàn)收和資料整理。 D、監(jiān)理工作準(zhǔn)備 ·熟悉施工圖和有關(guān)資料,編制監(jiān)理實(shí)施細(xì)則。 監(jiān)理工程師在工程開(kāi)工前應(yīng)熟悉有關(guān)施工圖紙,了解設(shè)計(jì)要求。明確工程各構(gòu)成部分,專業(yè)工種和工序之間的關(guān)系。參加設(shè)計(jì)交底和圖紙會(huì)審。對(duì)工程特點(diǎn)、難點(diǎn)和關(guān)鍵部位做到心中有數(shù)。熟悉相關(guān)標(biāo)準(zhǔn)、規(guī)范、規(guī)程和有關(guān)技術(shù)資料。編制監(jiān)理實(shí)施細(xì)則。 ·工現(xiàn)場(chǎng)質(zhì)量管理制度建設(shè) 檢查和督促施工單位確定或編制相應(yīng)的技術(shù)標(biāo)準(zhǔn),建立健全的質(zhì)量管理體系,施工質(zhì)量檢驗(yàn)制度和質(zhì)量水平評(píng)定考核制度。 上海申海建設(shè)監(jiān)理有限公司 上海中廣核技術(shù)產(chǎn)業(yè)研發(fā)中心項(xiàng)目監(jiān)理部 2010年8月 27- 1.請(qǐng)仔細(xì)閱讀文檔,確保文檔完整性,對(duì)于不預(yù)覽、不比對(duì)內(nèi)容而直接下載帶來(lái)的問(wèn)題本站不予受理。
- 2.下載的文檔,不會(huì)出現(xiàn)我們的網(wǎng)址水印。
- 3、該文檔所得收入(下載+內(nèi)容+預(yù)覽)歸上傳者、原創(chuàng)作者;如果您是本文檔原作者,請(qǐng)點(diǎn)此認(rèn)領(lǐng)!既往收益都?xì)w您。
下載文檔到電腦,查找使用更方便
4 積分
下載 |
- 配套講稿:
如PPT文件的首頁(yè)顯示word圖標(biāo),表示該P(yáng)PT已包含配套word講稿。雙擊word圖標(biāo)可打開(kāi)word文檔。
- 特殊限制:
部分文檔作品中含有的國(guó)旗、國(guó)徽等圖片,僅作為作品整體效果示例展示,禁止商用。設(shè)計(jì)者僅對(duì)作品中獨(dú)創(chuàng)性部分享有著作權(quán)。
- 關(guān) 鍵 詞:
- 中廣核 地下室 人防工程 監(jiān)理 實(shí)施細(xì)則
鏈接地址:http://m.kudomayuko.com/p-1200917.html